This guide is intended as an aid and there is no substitute for reading the full standard. Cfp 248 zone conventional fire alarm control panel universal. The model 5207 is an 8 zone fire alarm control panel expandable up to 16 zones with a dig ital communicator that meets nfpa 72 requirements. Together with automatic fire suppression systems, fire detection and alarm systems are part of the active fire protection systems found in many occupan. Ctec cfp 2, 4 or 8 zone conventional fire panel discount. Fire alarm annunciator system trouble resound tone silence remote alarm remote trouble municipal box tb1 tbl j1 j2 765 1 limited filename. The maximum number of devices per zone is 25, and the panel is suitable for installation with the apollo series 65 smoke and heat detectors. See requirements in part 2 3 remote anunnciator faa provides lcd display with a text statement of the panel status andor led lamps to indicate the status of the fire alarm system. Eatons 8 zone conventional fire system panel delivers a straightforward, intuitive interface that makes programming and maintenance simple. The control panel has supervised, silenceable alarm outputs for selfpowered sirens.
Upon completion you will have the tools to successfully install, program and startup a pfc series fire alarm system. This manual is not designed to teach fire alarm system design. The panel shall supervise and monitor both 2wire smoke detectors and contact alarm initiating devices on each twowire zone. A wide variety of 8 zone conventional fire alarm control panel options are. Eaton conventional 8 zone panel manual pr21521651703 150316, pinstconvinst.
Cfp 248 zone fire alarm panel the primary purpose of a fire alarm system is to provide an early warning of a fire so that people and animals can be evacuated and action taken to stop the fire as soon as possible all according to a predetermined plan. The range consists of 2, 4 and 8 zone control panels. Each detection zone has an alarm repeat output for selective management in the event of fire. Kentec sigma cp 8 zone conventional fire alarm panel k11080m2. The sfp10ud, 10 zone control panel with builtin communicators, provide reliable fire signaling protection for small to mediumsized applications. Available in a choice of 2, 4, 8 or 16 zone versions, the mf9300 range is designed for ease of installation and simple operation. Allows creation of default configurations in tdf teletek data files ready for use on site. A variety of faultfinding features keep the system in top condition, and class change and alert inputs allow it to have a. Premier fire alarm control panel maintenance manual pdf download.
In addition to the basic requirements of en542 or iso 72402, the panel may be configured to conform with the following. The panel has 8 detection zones in which detectors, call points and sounders are wired to the same pair of cables. Fstp8 2wire 8 zone conventional fire control panel. Advanced fire training manual potter electric signal. Class change and alert inputs, plus auxiliary faults, reset remote and auxiliary fire outputs functions including zone test, non latching zones, programmable delays and coincidence ancillary connections for up to 8 twowire repeaters and a relay board. The model 5207 is an 8zone fire alarm control panel expandable up to 16 zones with a dig ital communicator that meets nfpa 72 requirements. Cfp 28 zone alarmsense panels ctec fire alarms call. A wide variety of 8 zone conventional fire alarm control panel options are available to you, such as personal.
The ease with which it can be expanded, its flexible input. Fire alarm control panel safety issues there is no need to open this fire alarm during normal operation. Dfu7001001 rev 2 petersfield business park, bedford rd, petersfield, hampshire gu32 3qa tel. A network capability from 2 to 126 panels, makes the cf300 flexible for a. The control panel has supervised, silenceable alarmoutputs for selfpowered sirens. If surface mounting add d1 and d2 to obtain depth dimension. If the detector alarm is confirmed, the control panel enters the fire state and the alarms are activated throughout the. Manual fire alarm isolate switch instruction leaflet. Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, onboard fire. The horizon range has been designed with both installer and end users requirements in mind. Cfp 248 zone conventional fire alarm panel fire l rm systems n overview the primary purpose of a fire alarm system is to provide an early warning of a fire so that people and animals can be evacuated and action taken to stop the fire as soon as possible all according to a predetermined plan.
Cfp 24 8 zone fire alarm panel the primary purpose of a fire alarm system is to provide an early warning of a fire so that people and animals can be evacuated and action taken to stop the fire as soon as possible all according to a predetermined plan. With the ctec, lpcb certified conventionalfire alarm control panel 8zone, you can split your system into 8 different zones. Webinars potter provides distance learning with a live trainer on a variety of topics. Mounting the fire alarm panel it is recommended that the panel s door be removed to avoid accidental damage. Alarms may be raised automatically, by smoke or heat detectors, or manually by a person. Cfp economy 8 zone conventional fire alarm panel by ctec. Any work carried out on this system must be performed by a competent person who is familiar with this type of system. Each detection zone has an alarmrepeat output for selective management in the event of fire. All webinars are completely free of charge and have multiple dates and times for anyones schedule.
Ctec cfp 8 zone conventional fire panel lpcb approved. Addressable fire alarm panel for large sites cf3000 eaton. The contractor shall supply a 5 zone, fully supervised fire alarm control panel. Issue 1 idde catalog x small uilding fire alarm solutions 100616 technology that saves lives overview kidde brand conventional fire alarm systems consist of 5 and 10 zone fire alarm control panels facp, an optional integrated. This will give you an accurate idea of where the alarm was triggered. Introduction the first standards for fire detection and alarm systems in the united states dates back to the 1800s. Code description fx2201 conventional 1 zone panel fx2202 conventional 2 zone panel fx2204 conventional 4 zone panel fx2208 conventional 8 zone panel. Mounting the fire alarm panel infinity 8 installation manual 3. The sfp10ud, 10zone control panel with builtin communicators, provide reliable fire signaling protection for small to mediumsized applications. The infinity conventional fire alarms kits are an ideal starting point for any conventional fire system. Conventional fire alarm control panels iso9001 engineering and manufacturing quality system certified to international standard iso9001 made in the u.
The sfp10ud, sfp10udr red backbox, are a ul listed, 10 zone fire alarm control panel with a builtin digital alarm communicator transmitter dact and remote site uploaddownload capability. The panel operates in offnormal mode any time an event is introduced into the system. See requirements in part 2 f remote annunciator faa provides lcd display with a text statement of the panel status andor led lamps to indicate the status of the fire alarm system. The control panel shall be complete with five style b class b alarm. The infinity fire alarm control panel is available in. Fx22003300 mb steel back box for use with fx220248 mfalog fire alarm system log book product codes. Fire alarm control panel 8zone fire protection online. Conventional 28 zone fire systems ctec fire alarms. Zone alarm silence switch activation of this switch when a zone alarm is sounding, silences the zone alarm. Firesafe 8 zone fire panel with batteries fcfp8n cef. Kentec sigma cp 8 zone conventional fire alarm panel k11080m2 the sigma cp range consists of a series of conventional fire alarm control panels designed in accordance with european standards bs en542 and bs en544 fire detection and fire alarm systems control and indicating equipment.
This equipment will operate safely provided it has been installed correctly in compliance with the installation manual. Operating manual and log book for the range of 1,2,4 and 8 zone. This document is not intended to be used for installation purposes. A variety of faultfinding features keep the system in top condition, and class change and alert inputs allow it to have a secondary. While these first fire alarms were simplistic, advances in technology have resulted in fire alarm systems that can be intimidating in their complexity. Fire alarm a fire alarm is annunciated when a detector detects smoke or heat, a manual call point is operated, or an input is active. Advanced fire training manual 8700055 rev h 0517 section 1.
Ms 2e 2zone fire alarm control panels conventional fire alarm control panels df52211. Light the general fire led and appropriate zone fire leds on the front of its enclosure. Conventional fire control panel operation and maintenance manual. It highlights some of the main considerations in system design. Single dwelling per zone zonal confirmation alarm when a detector alarm is activated on this type of zone, all sounders on the zone are activated and the control panel carries out the configured number of confirmation checks. Fault monitoring all circuits must be checked for line integrity. The fire alarm resumes if the fire condition is continued after a predetermined period of time 2, 4, 6, 8 min. Scroll led test flt tone when the premier sx fire alarm panel is set into alarm by a detector or manual call point located in a zone that is not already in alarm it will. Infinity 2, 4 or 8 zone fire alarm kit discount fire supplies. As a default, the panel is configured without delays to outputs. The sfp5udc, 5zone control panel with builtin communicators, provide reliable fire signaling protection for small to mediumsized applications. The sfp5udc and sfp5udcr red backbox is a ul listed, 5zone fire alarm control panel with a builtin digital alarm communicator transmitter dact and remote site uploaddownload capability. Cfp economy 8 zone conventional fire alarm panel by ctec lpcb certified to en5424, ctecs cfp 8 zone economy fire alarm panel offers an array of user and installerfriendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, it includes eight detector zones, four conventional sounder circuits, class change and alert inputs, onboard.
Properly installed and maintained fire detection and alarm systems can help to increase the survivability of occupants and emergency responders while decreasing property losses figure 14. Fireshield singlezone panel installation and operating. Also, the termination pcb could be removed and stored in a safe place, while fixing the back box to the wall. Iris and iris pro are addressable fire alarm panels with 1 to 4 loops and. Infinity 2, 4 or 8 zone fire alarm kit discount fire.
Dil selectable conventional or twin wire savwire set up per zone integral 2. It has 8 zones, each supports up to 32 detectors, for a maximum of 256 detectors. We try to keep our product information uptodate and. Lpcb certified to en5424, ctecs cfp 8 zone conventional fire alarm panel offers an array of user and installerfriendly features at a very competitive price. Mf9300 range control panel overview the menvier mf9300 is a range of high specification conventional control panels designed for a wide range of building types and sizes at a competitive price. With a capacity of 200 addresses and detailed cause and effect programing, itdelivers a comprehensive user interface and logical menu structure. During an alarm, the panel will start its sounders, and indicate which zone has the fire. It also causes a fire verification signal to be transferred to an emergency pa system. Page 1 of 8 data sheet k850050126 not to be used for installation purposes. The kits are available with a 2, 4 or 8 zone panel and mixture of devices which can be expanded if required. Ctecs awardwinning cfp conventional fire panel is lpcb certified to en54 parts 2 and 4 and offers an array of user and installerfriendly features at a very competitive price. Colour coded button interface makes it simple to use. Nfs eight zone conventional fire alarm panel, complete with fire and fault relay module and capacitor end of line eol for detector removal monitoring. Ulc s 53704 verification of fire alarm systems fire alarm system modifications who may perform fire alarm system modification work generally a trained certified technician can replace existing devices on a one for one basis with the same or new type of device changereplace fire alarm paneltransponder components including batteries.
In normal mode, the control panel monitors the system. Vigilant f3200 8zone fire indicator panel brochure tyco safety. M 32417 page 1 of 8 nfs2 640e intelligent addressable fire alarm system intelligent fire alarm control panels dn7111. The subsequent actions depend on the actual configuration but generally. The sfp10ud, sfp10udr red backbox, are a ul listed, 10zone fire alarm control panel with a builtin digital alarm communicator transmitter dact and remote site uploaddownload capability. Lpcb certified to en5424, ctecs cfp twowire 8 zone alarmsense fire panel is designed to work with apollos alarmsense range of detectors, call points, sounders and visual indicators. Most conventional fire systems work with two pairs of wires per zone. Alarm lines are monitored for open circuit and short. With the ctec, lpcb certified conventionalfire alarm control panel 8 zone, you can split your system into 8 different zones.
68 966 817 1448 816 797 142 743 710 106 425 1327 1291 776 495 156 23 1243 1510 1543 121 934 14 710 616 228 510 751 911 942 327